bullet

FVC3000 Fume Hood Controller

bullet

BAPI-Stat 3 Wall Temp/Humidity Wall Sensor

bullet

Apex Premier High Performance Fume Hood Monitor

bullet

Apex Basic High Performance Velocity Alarm

bullet

BVT-2000 Blade Valve - Electronic Control Valve

bullet

FVC-2100 / FVC-2000 Velocity Sensing FVC 2600 Sash Based Fume Hood System

bullet

IAQ Outdoor Air Measurement System

bullet

PVP-4000 Airflow Control Valve

bullet

PVS-4000 Airflow Control Valve

bullet

PVT-2000 Airflow Control Valve

bullet

SPM-2000 IsoTek Space Pressurization Monitor System for Isolation Rooms and Laboratories

bullet

TFP-5000 Differential Pressure Airflow Probes

bullet

VT-2000 VorTek Flow Technology Measurement

bullet

VT-5000 VorTek Flow Technology Measurement

bullet

VT-7000 VorTek Flow Technology Measurement

bullet

VT-8000 VorTek Flow Technology Measurement

   
 

NEW FVC 3000
Fume Hood Controller

 

A fume hood is controlled for various reasons. The first concern should be safety of the operator, and the second should be energy savings. The industry has gone through several phases of controlling fume hoods over the years and still, there are different preferences as to how a hood should be controlled. Tek-Air has made it easy with the FVC 3000 Fume Hood Controller. The consumer has several options with one fume hood controller, the FVC 3000, that can be configured to fit their needs.  

 

What's new on the Tek-Air FVC 3000 Fume Hood Controller?

  • New Intuitive and Informative Color Display
  • No External Configuration Tools required
  • Supports vertical and / or horizontal sash configurations
  • Configurable for direct face velocity or volumetric control
  • More Energy Saving modes than before including:
    • Set Back for Energy Savings
    • Low Set Back for additional Energy Savings
    • Sleep Mode-Hibernate (Sash Control Only)
    • Hood Disable-Shutdown (all Modes
  • Field Upgradeable with Micro SD Card
  • Simple Balancer Interface
  • Controls low flow fume hoods
  • Easy to clean display panel
  • Works alone or with other controllers for tracking flaws in lab spaces
  • Greater flexibility with Set Points and Alarm Points
  • Pass Code protected for limited access
  • Ability to copy configurations to similar hoods
  • Peer to Peer communication with other Model 3000 hoods
  • BACnet MSTP I/P compatible



Technical Data Sheet
Installation Manual

 

 
   
 

Blade Valve
ELECTRONIC AIRFLOW CONTROL VALVE

 

The Tek-Air BVT2000 Series Airflow Control Valve uses the tried and true blade damper concept, and incorporates the dependable Vor-Tek Airflow sensor as an integral part of this assembly. The valve's postion is commanded by a separate controller's signal to the Belimo actuator.This Blade Valve assembly can be ordered in Fail Safe (FSC or FSO), or Fail in Last Place (FLP), and used with any controller that has 2-10 Vdc Analog inputs and outputs.
 

 

Applications

  • classrooms

  • laboratories

  • clean rooms

  • industrial process manufacturing

  • hospitals

Advantages

  • Electric Actuation

  • Fast Speed of Response

  • Integral Flow Staightener Optional

  • Low Differential Pressure for Maximum Flow

  • True Flow Feedback - Vortek Airflow Sensing

  • Static Pressure Independant with Controller PID Loop

  • No Springs to wear out

  • No Scheduled Maintenance



Technical Data Sheet
Installation Manual

 
  
 

BAPI-STAT
Combination Temp / humidity Wall sensor

 

The Bapi-Stat 3 features a large display and membrane pushbuttons for wipedown cleaning. It is available as a temperature sensor alone or as a combination temp/humidity sensor. Depending on the options selected, the BAPI-Stat 3 can display room temperature, temperature setpoint, room humidity, humidity setpoint and override status. 

 

Applications

  • Room Temperature and Humidty monitoring within the Lab

Advantages

  • Large LCD display with offset adjustment

  • Easy up / down arrows for setpoint

  • Membrane pushbuttons

  • Analog outputs for most controllers

  • Various type of temperature sensors

  • Contact outputs for Occupied Status

  • Tek-Air Logo in the room for the customer


Technical Data Sheet

 
   
 

APEX Premier
high performance fume hood monitor

 

The Apex Premier™ utilizes state-of-the-art technology to provide the highest level of performance achievable in a fume hood monitor.  The heart of the Apex Premier is the smart sensor module which is responsible for accurate, repeatable and instantaneous measurement of fume hood face velocity.  Face velocity measurement is made by an ultra-sensitive micro-bridge mass airflow sensor with a response time of less than 3 milliseconds.  The analog signal provided by the micro-bridge is digitized by a high-resolution A/D converter, then further enhanced and factory calibrated over the operating velocity range by an automated test an calibration system. 

 

Applications

  • All types of fumehoods including high performance low flow hoods, variable volume and constant volume

Advantages

  • Microprocessor-based performance

  • Microbridge mass airflow sensor technology and advanced automated factory calibration

  • Real-time graphical display of face velocity

  • Internal menu driven setup and field calibration

  • Programmable mute button, output relays for Purge or Alarm, digital inputs for alarm or setback

  • Entire system settings viewable via one button

  • Password protected calibration configuration

  • Self-contained face velocity sensor


Technical Data Sheet

 
   
 

APEX BASIC
HIGH PERFORMANCE VELOCITY ALARM

 

Tek-Air is proud to introduce the APEX Basic Velocity Alarm to the Critical Environments Industry. The APEX Basic was developed by Tek-Air to provide the industry with a cost-effective, accurate and reliable velocity alarm to help ensure a safe operating environment for laboratory personnel. The APEX Basic is suited for use on all types of fume hoods and Biological Safety Cabinets.

 

Applications

  • All types of fumehoods and biological safety cabinets

Advantages

  • Simple to Install and Operate

  • Continuous Monitoring of Velocity

  • Reliable, Accurate and Fast Speed of Response

  • Unoccupied Mode - Digital Input

  • Alarm Status to BAS - Alarm Relay

  • Visual Status Indicators

  • Audible Alarm


Technical Data Sheet

 
   
 

FVC-2100/2200
velocity sensing fume hood Control system

 

For basic constant velocity fume hood control using face velocity measurement, Tek-Air recommends model FVC-2100 or FVC-2200.  The two systems utilize identical components with the exception of duct exhaust volume sensing equipment added to the FVC-2000 to provide flow limit control.  Tek-Air's VorTek airflow traverse probes provide volumetric measurement in that application.

Both systems provide face velocity control using the "sidewall sensing" method.  The basic system consists of a controller, sensor probes, display unit, I/P converter, and exhaust air control valve.  The controller is typically wall-mounted above the fume hood.  The thermal face velocity sensor in the controller connects via PVC tubing to the hood probe mounted on the inner sidewall of the fume hood and the reference probe mounted outside the fume hood interior.

The FVC2100 and FVC2200 also works well with the AV3000 and BVP4000 Control valves when the I/P output is wired to the fast acting electric actuator.

 

Applications

  • economical, high performance VAV system capable of instantaneous response to changes in sash opening and air handling systems

  • designed for vertical and horizontal fume hoods

  • true "closed loop control system" providing speed and accuracy based on true Face Velocity Measurement ("Through the Wall")

  • additional night-time face velocity setback feature

Specifications
Manuals
Technical Data Sheet

 
   
 

FVC-2600
Sash Sensing Fume Hood COntrol System

 

For basic constant velocity fume hood control using sash position sensing, Tek-Air recommends model FVC-2600.  This system utilizes sash position to reset the volume setpoint in the duct exhaust volume sensing equipment.  Tek-Air's VorTek airflow traverse probes provide volumetric measurement in that application.

The result of the exhaust volume changing based on sash position, allows the controller to maintain a constant face veloicty at the opening of the sash.  The basic system consists of a controller, sash sensor(s), display unit, i/p transducer, and an exhaust air control valve with integral flow measurement sensors.  The controller is typically wall-mounted above the fume hood.

The FVC2600 also works well with the AV3000 and BVP4000 Control valves when the I/P output is wired to the fast acting electric actuator. 

 

Applications

  • economical, high performance VAV system capable of instantaneous response to changes in sash opening and air handling systems

  • designed for vertical and horizontal fume hoods

  • true "closed loop control system" using Sash Position to reset the Volume Set Point of the Hood Control Valve.

  • additional night-time face velocity setback feature

Specifications
Manuals
Technical Data Sheet

 
   
   
 

IAQ2000
IAQ Outdoor Air Measurement system

 

The IAQ Outdoor Air Measurement system is designed for accurate measurement in outdoor air inlet situations where low velocity, dirt, moisture and turbulence affect other products in quantifying the volume of fresh air to the building. The IAQ utilizes a Patented air flow sensor in conjunction with a transducer and monitor assembly, which incorporates intuitive directions for the user in setting up and maintaining the product.

 

Applications

  • after inlet louvers on an outdoor air inlet

  • under the rain hood of roof top units

  • large ducts with low velocities

Advantages

  • velocities as low as 60 fpm

  • not affected by moisture

  • large areas with low velocities

  • works in turbulent air

  • stable transmitter output

  • user friendly

Technical Data Sheet
Manuals

 
   
 

PVP-4000
airflow control valve

 

The PVP-4000 Airflow Control Valve consists of a VorTek VT-4000 airflow measuring probe mounted in the inlet of a PRD airflow control valve, for direct connection to an FVC fume hood or SmartLab controller.

 

Applications

  • fume hood, room supply air to lab exhaust to canopy hood applications

  • available with rectangular or round inlet and outlet

  • can be ordered in galvanized steel or stainless steel construction

  • well-suited to contaminated and corrosive airstreams

  • factory-mounted cable connects directly to Tek-Air SmartLab and FVC-2000 fume hood controllers, without need for a
    transmitter

  • can be used for variable or constant volume applications

 
   
 

PVS-4000
airflow control valve

 

The PVS-4000 Airflow Control Valve consists of a Vortek VT-4000 Airflow Measuring Probe mounted in the inlet of a PRD Airflow Control Valve, and an SLC-2000 SmartLab Controller.

 

Applications

  • room supply air to lab exhaust, canopy hood applications, etc.

Advantages

  • programmable via a PC outfitted with a software and ARCnet card and Tek-Air's Graphic User Interface

  • available with rectangular or round inlet

  • can be ordered in galvanized steel or stainless steel construction

  • well-suited to contaminated and corrosive airstreams

  • equipped with a factory mounted cable that connects directly to SLC-2000 without the need for a transmitter

 
   
 

PVt-2000
airflow control valve

 

The PVT-2000 is a precision airflow control valve consisting of a Vortek VT-2000 airflow measuring device mounted in the inlet of a PRD airflow control valve.  A factory-installed current-to-pressure (I/P at 4-20 ma) or voltage-to-pressure (E/P at 2-10 vdc) transducer takes an electronic control signal from any airflow controller to modulate the PRD. The Vortek transmitter provides a
4-20 ma, 1-5 vdc or 2-10 vdc output to the airflow controller.  The use of these industry standard signals allow use with most airflow and temperature controllers presently on the market. A 24 vac or dc power source is required for the Vortek transmitter. Both the I/P and E/P are loop-powered, two-wire connection. Both the I/P and E/P require 20 psi clean, dry instrument air supply to operate.

 

 Applications

  • room supply air and lab exhaust controls

  • cleanroom pressurization control

  • hospitals

  • industrial and process facilities

Advantages

  • available with rectangular or circular inlet and outlet,

  • can be ordered in galvanized steel or stainless steel construction

  • well-suited to contaminated and corrosive airstreams

 
   
 

Iso-tek spm-2000

 

The Iso-Tek space pressurization monitoring system is designed for use in a wide variety of applications that necessitate the monitoring of airflow from one room to another.  The monitor system can be configured by the user for bi-directional measurement of either air velocity in feet per minute (fpm), or air pressure in inches of water column ("wc").

 

 Applications

  • hospitals, including patient isolation, autopsy and operation rooms

  • prisons and shelters

  • chemical laboratories

Advantages

  • continuous monitoring at a fraction of the cost of manual techniques

  • meets ANSI and AIHA Lab Safety Standard, Z9.5-1992

  • rugged construction

  • fewer installation constraints

  • immunity to fouling by lint and dirt

Technical Data Sheet
Manuals

 
   
 

TFP-5000
Differential pressure airflow probes

 

The TFP-5000 Airflow Measurement Probes have an extremely low YAW angle effect throughout the 30° range, an improved signal-to-noise ratio, and they generate an amplified differential pressure signal, improving the ability to make low velocity measurements.  Insertion Probes can easily be installed in either new or existing ductwork by cutting small entry holes in either side and installing the sensors across the duct area.  Where the sensor must be removed for periodic inspection or cleaning, insertion probes provide an excellent measurement solution.  The TFP-5000 probes are manufactured in one-inch increments in lengths from four to 146 inches long, for rectangular, circular, and oval ductwork.  Achievable accuracies are typically within 2% of actual airflow. 

 

 Applications

  • commercial and institutional applications

  • hospitals

  • cleanrooms

 
   
 

VT-2000
VorTek flow technology measurement

 

The VT-2000 Airflow Measurement Probe consists of multi-sensor probes available as insertion probes or in pre-assembled airflow stations.  Individual sensors provide frequency pulse outputs which are directly proportional and linear to airflow velocity.  These digital signals are totalized in the companion transmitter and are converted to a 4-20mA, 1-5 or 2-10 VDC output, linear to flow.  Units are available with one to four sensors, in sizes as small as 4" diameter up to four square feet.  Either 24 VAC or 15 to 35 VDC power is required for operation.

 

Applications

  • Specifically designed for use in small ducts as a high performance alternative to Pitot stations with velocity pressure transmitters, and thermal devices

  • flow measurement applications in industrial and process flow measurement, semi-conductor, and pharmaceutical cleanrooms

  • laboratories

  • animal rooms

  • operations rooms

  • HEPA filter systems where flow monitoring is critical to system performance

 

Advantages

  • linear sensor output

  • true velocity averaging

  • drift-free operation

  • ten-to-one flow turndown

  • impervious to dirt and other suspended materials in the airstream

Specifications
Manuals
Drawings

 
   
 

VT-5000
VorTek flow technology measurement

 

Velocity measurement is accomplished by Tek-Air's unique, patented, VorTek sensors.  VorTek sensors utilize proven vortex shedding phenomena to measure the true airflow velocity independent of changes in temperature, density, and humidity which affect Pitot and thermal airflow measurement systems. 

The VT-5000 Airflow Measurement Probe consists of multi-sensor probes inserted in the ductwork where airflow is to be measured and transmitted. Individual sensors on the probes provide pulse frequency electronic output signals which are directly proportional and linear to the airflow velocity. These signals are totalized in the companion transmitter and converted to an industry standard, 4-20mA output. (1-5 VDC or 2-10 VDC are also selectable by jumper).

 

 Applications

  • VAV fan synchronization for large inlet fans (greater than 24" Diameter)

  • cleanroom flow tracking and control of pharma semi-conductor, process/industrial, hospital and R&D facilities, filter monitoring , and lab pressurization

  • filter monitoring

  • lab pressurization

Advantages

  • linear sensor output

  • true velocity averaging

  • drift-free operation

  • ten-to-one flow turndown

  • impervious to dirt and other suspended materials in the airstream

Specifications
Manuals
Drawings

 
 
   
 

VT-7000
VorTek flow technology measurement

 

The VT-7000 Airflow Measuring Device consists of multi-sensor probes mounted on a bar and installed in the inlet of large fan inlets.  Individual sensors on the probe provide frequency pulse type electronic output signals which are directly proportional and linear to airflow velocity.  These signals are totalized in the companion transmitter and converted to an industry standard, 4-20mA output.  (1-5 VDC or 2-10 VDC are also selectable by jumper.)

 

 Applications

  • VAV fan synchronization for large inlet fans (greater than 24" Diameter)

  • cleanroom flow tracking and control of pharma semi-conductor, process/industrial, hospital and R&D facilities, filter monitoring , and lab pressurization

Advantages

  • linear sensor output

  • true velocity averaging

  • drift-free operation

  • ten-to-one flow turndown

  • impervious to dirt and other suspended materials in the airstream

Specifications
Manuals
Drawings

 
   
 

VT-8000
VorTek flow technology measurement

 

The VT-8000 Airflow Measuring Device consists of multiple sensors which are mounted on the fan to provide frequency pulse type electronic output signals which are directly proportional and linear to airflow velocity.  These signals are totalized in the companion transmitter and converted to an industry standard, 4-20mA output.  (1-5 VDC or 2-10 VDC are also selectable by jumper.)

 

 Applications

  • VAV fan synchronization for small inlet fans (Less than 24" Diameter)

  • cleanroom flow tracking and control of pharma semi-conductor, process/industrial, hospital and R&D facilities, filter monitoring , and lab pressurization

Advantages

  • linear sensor output

  • true velocity averaging

  • drift-free operation

  • ten-to-one flow turndown

  • impervious to dirt and other suspended materials in the airstream

Specifications
Manuals